window.ga=window.ga||function(){(ga.q=ga.q||[]).push(arguments)};ga.l=+new Date; ga('create', 'UA-177780411-1', 'auto'); ga('set', 'forceSSL', true); ga('set', 'anonymizeIp', true); ga('require', 'displayfeatures'); ga('require', 'cleanUrlTracker'); ga('require', 'outboundLinkTracker'); ga('require', 'ec'); ga('send', 'pageview'); ga('set', 'nonInteraction', true); setTimeout("ga('send', 'event', 'read', '20 seconds')", 20000); Buy amp transformers | Tube Amp Doctor

Transformers

Close filters
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
 
from to
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
13 From 13
No results were found for the filter!
Laney Amplification
AOR30P Netztrafo für Laney AOR30, Pro Tube Serie
Power transformer for Laney AOR30, Pro Tube Series
until further notice undeliverable! substitude with minor electrical modifications: 039044! Power transformer for Laney AOR30, Pro Tube Series Primary: 120V #1 0V #3 120V #6 110V #7 0V #9 Secondary: HV #10 0V #11 50V #12 12V #13 0V #14...

€129.00 *
Remember Part Number: AOR30P
Laney Amplification
LC30P Netztrafo für Laney LC30, VC30 und GC30V (p/n 6073)
Power transformer for Laney LC30 (p/n 6073)
Power transformer for Laney LC30, VC30 und GC30V (p/n 6073) original Laney part, toroidal core Primary: 240V BROWN 230V RED 0V BLUE Secondary: 220V RED 0V RED 17V BLUE 0V BLACK 17V BLUE 3,2V WHITE 0V BLACK 3,2V WHITE

€99.00 *
Remember Part Number: LC30P
Tube Amp Doctor GmbH
561843 Netztrafo für Mesa Boogie Mark V:35
power transformer for Mesa Boogie Mark V Thirty-Five
power transformer for Mesa Boogie Mark V (Mark Five:35) Thirty-Five and Transatlantic TA-30 230/240V, #561843 Exportversion, replaces the 120V domestic version (561842) For a conversion to 230V/240V additional parts are needed (see...

€169.00 *
Remember Part Number: 561843
Spares for Fender
125A20B Reverb Drive Transformer, Fender®, Boogie®
Reverb Drive Transformer, Fender®, Boogie®
Reverb drive Transformer, suitable for allmost all Fenders since 1964(= 022921) Custom made for TAD in the USA! primary used by all Fender® models with tube reverb from 1963-1990 and Reissue models like: Fender® Princeton Reverb Fender®...

€39.81 *
Remember Part Number: 125A20B
Marshall Amplification PLC
M100R Reverb Drive Transformator, Marshall®, JCM800: 2210 etc
Reverb Drive Transformer, Marshall®, JCM800: 2210
Reverb drive Transformer, used in the famous JCM 800 Channel switch amps 2210, 2205, 4210, 4211, 4212. Original part #: D2967 and TXRE-00002

€35.60 *
Remember Part Number: M100R
Spares for Fender
004-7605-000 Reverb Transformer, Fender® Style Vibroking, 63` Tube Reverb
Reverb Transformer, Fender® Vibroking, 63` Tube Reverb
Fender style reverb drive transformer 047605 (identical with old Fender p/n: 012990, 125A12A) used in the Fender Vibroking with 6V6 reverb driver tube and the 63` Fender Reverb Reissue Custom made for TAD in the USA, paper stick wound!...

€49.00 *
Remember Part Number: 004-7605-000
Tube Amp Doctor GmbH
VT1000ESG-S TAD Vorschalttrafo mit Gehäuse 1000VA
TAD Step-Down transformer with enclosure 1000VA
STEP DOWN transfomer for connecting 110-120V US devices to 220-250V AC supply 1000VA, 230/115V black metal enclosure, with lighted mains switch and fuse, 2 US-3-conductor mains sockets with propper grounding 1000VA is plenty power,...

€129.00 *
Remember Part Number: VT1000ESG-S
Tube Amp Doctor GmbH
VT100ESG-S TAD Vorschalttrafo mit Gehäuse 100VA
TAD Step-Down transformer with enclosure 100VA
100VA, 230/115V with lighted switch, suitable for Fender Champ, Princeton Tweed, Vibro Champ, Pro Junior, ´63 Tube Reverb ;Silverface Musicmaster Bass Amp; Gibson GA-5; Mesa Boogie Triaxis, Quad Preamp Dimensions (LxWxH): 16.3 x 12.1 x...

€45.01 *
Remember Part Number: VT100ESG-S
Tube Amp Doctor GmbH
VT300ESG-S TAD Vorschalttrafo mit Gehäuse 300VA
TAD Step-Down transformer with enclosure 300VA
300VA, 230/115V, black steel enclosure, lighted AC-mains-switch, external fuse, 2 US-AC-Outlets , suitable for: Fender Princeton Amp, Princeton Reverb Amp, Deluxe Reverb Amp, Vibrolux Reverb Amp, Super Reverb Amp, Bandmaster Reverb (also...

€69.00 *
Remember Part Number: VT300ESG-S
Tube Amp Doctor GmbH
VT500ESG-S TAD Vorschalttrafo mit Gehäuse 500VA
TAD Step-Down transformer with enclosure 500VA
500VA, 230/115V, black steel enclosure, lighted AC-mains-switch, external fuse, 2 US-AC-Outlets, suitable forFender Tweed Twin, Twin Reverb, Showman, Dual Showman, Bassman 100, 135; Marshall 100W; Hiwatt 100, Orange 120W, Mesa Boogie MK...

€89.00 *
Remember Part Number: VT500ESG-S
Tube Amp Doctor GmbH
9460345 Netztrafo, Heizung, Ampeg SVT Classic, SVT Heritage
Transf. Filament for: Ampeg® SVT Classic
Transf. Filament for: Ampeg® SVT Classic, Export Could also replace the 94-602-35 comes with top shroud like pictured lamination: 3 3/8" mounting on 2 1/4" x 2 13/16" Primary: 770005 0V Violet 100V Grey 120V Brown 0V White 100V Blue 110V...

€145.60 *
Remember Part Number: 9460345
Spares for Fender
039044 Netztrafo für Fender Champ 25SE
Transf. Mains for Fender Champ 25SE
Transf. Mains for Fender Champ 25 SE and Champ 25 Lamination: 3", Stack 2" Dimensions: L x W x H: 76mm x 64mm x 93mm Installation height: 80mm fits Laney AOR30 also! (increase R75 , R76, filament balance with 2x100R) Also perfect for DIY...

€124.90 *
Remember Part Number: 039044
Tube Amp Doctor GmbH
LJ200P NETZTRAFO für Luxor Junior 200
Transf. Mains for Luxor Junior 200
Transf. Mains for Luxor Junior 200 Lamination: EI120/35, Upright L x W x H: 96 x 101 x 125 MADE IN GERMANY! primary: 0V Grey 110V Black 125V Blue 140V Green 160V Yellow 220V Red 240V White secondary: 285V@200mA Red 0V Yellow 285V Red...

€119.00 *
Remember Part Number: LJ200P
Tube Amp Doctor GmbH
SLO100P Netztrafo für: Soldano® SLO100
Transf.MAINS for: Soldano® SLO100
Transf.MAINS for: Soldano® SLO100 Now available again! Superior quality and stability! lamination: 4.5" Stack: 2" mounting on 95mm x 86mm W x D x H: 115mm x 122mm x 98mm primary: 0 ORG 120 GRN 230 BLU 240 WHT secondary: 360 450mA VIO 60...

€212.20 *
Remember Part Number: SLO100P
Tube Amp Doctor GmbH
SE-H2 Stehende Induktivität, 09P, 680µH
vertical inductance, 09P, 680µH
vertical inductance, 09P, 680µH elated inductance middle-rated DC current. • tolerance: ±10 % • inductor value at 20 KHz • Q min.: 35 • SRF min.: 1,9 MHz • DCR max.: 1,9 Ohm • Rated DC I: 350 mA

€0.80 *
Remember Part Number: SE-H2
13 From 13

Transformers - the right voltage for great sound

Tube amplifiers are sensitive creatures. They are susceptible to voltage fluctuations, excessive wear, and react almost allergically to incorrect system components. To generate the right sound, amplifiers require special converters that reliably generate the required voltages and currents, and provide a perfect match between the output stage tubes and the speakers.

We use only proven branded technology from suppliers used by big names like Marshall, Fender, and Co. for our transformers.

Matching transformers for every project - a brief overview

Transformers perform their tasks at various key points within an amplifier and thus influence the operation, behavior, and ultimately the sound of the respective device in various ways.

We offer a large number of products for all conceivable applications:

Output transformers

These devices for tube amplifiers are responsible for adapting the high-impedance signals of the electron tubes to the impedance of the speakers used. Speakers typically operate at 4, 8, or 16 ohms impedance - output converters adjust the signal accordingly.

Reverb driver transformer

Amplifiers that use a real reverb tank to create reverb effects are particularly found in classic guitar amps. To drive the reverb tank, a special reverb driver tube is typically used. This then drives the tank with the help of the reverb driver transformer - et voila: a creamy, subtle reverb delights the ear!

Mains transformer

Adapting the voltage of the power grid to the needs of one's own amp is the basic requirement for our beloved sound generator to do anything at all. Converting mains voltage into the internal requirements is the task of the mains transformers.

Step-down transformer

Step-down transformers adapt the European mains voltage (230V) to the voltage required by US devices (117V): We offer our TAD step-down converters in the highest quality so that even old original US amps can reliably operate again without modification!

Transformer covers

Not only do we offer the voltage converters themselves, but also the matching transformer covers to our customers. The appropriate metal caps for El 114, El 76, El 96, El 84 are used in various color variants.

New construction project vs. restoration

We support our customers in making their tube amplifier sound good again - whether it's a newly built, personalized amp or an old Fender classic. We provide our customers with the appropriate spare parts and voltage converters for their projects, according to the original specifications of the manufacturers.

Order transformers, branded tubes, and more from Tube Amp Doctor

Electronic components for tube amps are our specialty - and have been since 1993. We supply our customers with the highest quality components at fair prices, ensuring that they are long-tested and suitable components. Our stock comprises over 650,000 components waiting for the next project.

Our specialists are always available to assist our customers with advice, support, and the necessary know-how. Visiting the doctor is fun with us!

Viewed